This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat SELP. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Rat SELP are added to the micro ELISA plate wells. Rat SELP in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Rat SELP.Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat SELP. The concentration of Rat SELP in the samples is then determined by comparing the OD of the samples to the standard curve.
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat TF. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Rat TF are added to the micro ELISA plate wells. Rat TF in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Rat TF.Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat TF. The concentration of Rat TF in the samples is then determined by comparing the OD of the samples to the standard curve.
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Rat T. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Rat T are added to the micro ELISA plate wells. Rat T in samples (or standards) competes with a fixed amount of T on the solid phase supporter for sites on the HRP linked detection antibody specific to T. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The concentration of Rat T in the samples is then determined by comparing the OD of the samples to the standard curve.
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to Rat VCAM-1/CD106. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Rat VCAM-1/CD106 are added to the micro ELISA plate wells. Rat VCAM-1/CD106 in samples (or standards) combines with the coated antibody and HRP linked detection antibody special to Rat VCAM-1/CD106.Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of Rat VCAM-1/CD106. The concentration of Rat VCAM-1/CD106 in the samples is then determined by comparing the OD of the samples to the standard curve.
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Sheep Cortisol. Samples (or Standards) and Horseradish Peroxidase (HRP) linked antibody specific for Sheep Cortisol are added to the micro ELISA plate wells. Sheep Cortisol in samples (or standards) competes with a fixed amount of Cortisol on the solid phase supporter for sites on the HRP linked detection antibody specific to Cortisol. Excess conjugate and unbound sample or standard are washed from the plate. The substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450±2 nm. The concentration of Sheep Cortisol in the samples is then determined by comparing the OD of the samples to the standard curve.
Lascia la tua email e seleziona le aree che vuoi seguire per ricevere novita di prodotto, approfondimenti tecnici e promozioni piu pertinenti.
Puoi scegliere le macro-aree Life Science e Diagnostica oppure le singole specializzazioni.
Seleziona uno o piu ambiti di interesse per ricevere comunicazioni piu utili e mirate.
Aggiornamenti su ricerca, strumentazione e applicazioni per il mondo Life Science.
Novita, approfondimenti e promozioni per laboratori diagnostici e flussi operativi.
2025 TEMA Ricerca - All Rights Reserved.